Gasoline Silent
T2600iS 2.2 kW Inverter Silent Petrol Generator
Model T2600iS · engine · 65 dB(A) at 7 m · 9 h at 50% load continuous running
T-15P-X silent petrol generator: 15 kW rated / 16 kW standby, 230 / 400 V 50 Hz. 999 L engine (465), 290 kg. 15 kW petrol silent set on the 465 engine — the entry point of the multi-cylinder petrol line.
Rated at 15 kW (18.8 kVA), the T-15P-X is a silent diesel generator set for 230 / 400 V at 50 Hz networks.
Drive comes from a 999 L 465 engine turning at 3000 rpm.
Weighing 290 kg, this is a fixed-installation set intended for factories, hospitals and mining sites where continuity of supply matters more than portability.
Shipping is efficient at volume: 30 pcs units in a 20 ft container and 70 pcs in a 40 ft, keeping freight cost per unit low.
SmallGen specialises in the export of small power equipment, and this model is part of that range. Before loading, the set is run on a resistive load bank up to its rated output, and the test video and nameplate photos are sent with the shipping documents.
| Model Number | T-15P-X |
| Rated Output Power | 15 kW |
| Max Output Power | 16 kW |
| Apparent Power (estimated, cosφ=0.8) | 18.8 kVA |
| Rated AC Voltage | 230 / 400 V |
| Frequency | 50 Hz |
| Engine Speed | 3000 rpm |
| Power Factor | 1.0 / 0.8 |
| Phase | Single / three phase |
| Starting System | Electric start |
| Noise Level (7m) | 72 dB(A) at 7 m |
| Engine Model | 465 |
| Engine Type | V-twin, four-stroke, air-cooled petrol |
| Displacement | 999 L |
| Bore × Stroke | 65 × 72 mm |
| Fuel Type | Unleaded gasoline 92# and above |
| Dimension (L×W×H) | 1130 × 700 × 870 mm |
| Net Weight | 290 kg |
| 20FT Loading | 30 pcs |
| 40HQ Loading | 70 pcs |
| Alternator | Shenchi (pure copper) |
| Breaker | Delixi |
| Battery | 12 V 36 Ah maintenance-free |
| Standard Features | AVR, electric start, oil alert, sealed silent canopy |
| Optional Features | ATS, remote start |
Swipe the table sideways to see all parameters.
* Loading quantities are estimated from carton dimensions and gross weight at 88% volume utilisation. Confirm the final figure with us before booking.
This output is sized for premises where the generator carries the whole load rather than a few circuits: a factory floor, a hotel, a hospital ward or a mining camp. Several motors can start simultaneously and there is headroom for air conditioning across multiple rooms. At this size the practical questions shift from whether it can start the load to fuel logistics — daily consumption and tank capacity matter more than peak capability.
How much fuel does it use?
Rated specific consumption is -. The - tank gives roughly - at rated load. Diesel consumption scales fairly linearly with load, so running at half load roughly halves hourly fuel use.
Can it run continuously?
Yes — diesel sets are built for sustained duty and are the normal choice where the machine runs several hours a day. Keep to the service intervals in the manual, particularly oil and filter changes: small diesel engines are far less forgiving of neglected oil than gasoline engines.
Can it be installed near houses or a clinic?
This is a silent-type set rated around 70–75 dB(A) at seven metres, the configuration normally specified for hospitals, hotels, offices and residential blocks. Installation still matters: a solid concrete pad and a position away from reflective walls will do as much as the canopy itself.
Gasoline Silent
Model T2600iS · engine · 65 dB(A) at 7 m · 9 h at 50% load continuous running
Open Frame
Model 6500 · 188F engine · · continuous running
Gasoline Silent
Model T-25P-X · 474 engine · 72 dB(A) at 7 m · continuous running