T2600iS 2.2 kW Inverter Silent Petrol Generator
Model T2600iS · engine · 65 dB(A) at 7 m · 9 h at 50% load continuous running
T4500iS inverter silent petrol generator: 3.6 kW rated / 4 kW peak, 230 V 50 Hz single phase. 157 cc four-stroke air-cooled engine, 6.8 L fuel tank, up to 7 h at 50% load, 70 dB(A) at 7 m. Clean sine-wave output with THD below 3%.
Rated at 3.6 kW (3.6 kVA), the T4500iS is a silent diesel generator set for 230 V at 50 Hz networks.
Drive comes from turning at 3600 rpm. The 6.8 L fuel tank gives 7 h at 50% load of continuous running.
At 22.5 kg the set is light enough for two people to move between sites, which suits small workshops, retail premises and households that need power in more than one place.
For volume orders, a 20 ft container takes 208 pcs and a 40 ft takes 481 pcs, which keeps freight cost per unit low.
SmallGen specialises in the export of small power equipment, and this model is part of that range. Before loading, the set is run on a resistive load bank up to its rated output, and the test video and nameplate photos are sent with the shipping documents.
| Model Number | T4500iS |
| Rated Output Power | 3.6 kW |
| Max Output Power | 4 kW |
| Apparent Power (estimated, cosφ=0.8) | 3.6 kVA |
| Rated AC Voltage | 230 V |
| Frequency | 50 Hz |
| Engine Speed | 3600 rpm |
| Power Factor | 1.0 |
| Phase | Single phase |
| Starting System | Recoil start |
| Noise Level (7m) | 70 dB(A) at 7 m |
| Fuel Tank Capacity | 6.8 L |
| Continuous Working Time | 7 h at 50% load |
| Engine Type | Single-cylinder, four-stroke, air-cooled, OHV |
| Displacement | 157 cc |
| Fuel Type | Unleaded gasoline 92# and above |
| Dimension (L×W×H) | 513 × 298 × 472 mm |
| Net Weight | 22.5 kg |
| 20FT Loading | 208 pcs |
| 40HQ Loading | 481 pcs |
| Alternator | Shenchi (pure copper) |
| Breaker | Delixi |
| Battery | Camel |
| Standard Features | Inverter control module, low-oil shutdown, overload protection, carry handle |
| Optional Features | Remote start, wheel kit, parallel operation cable |
Swipe the table sideways to see all parameters.
* Loading quantities are estimated from carton dimensions and gross weight at 88% volume utilisation. Confirm the final figure with us before booking.
This is the range that covers most small commercial loads: a shop with refrigeration, a restaurant with a freezer and blender, a clinic with a vaccine fridge and steriliser, or a workshop running hand tools and a small compressor. One air conditioner of 1–1.5 kW can be carried alongside general lighting, and a borehole pump of up to about 1.1 kW will start reliably. The limit is two large motors starting at the same moment — that is where this size runs out of headroom.
How much fuel does it use?
Rated specific consumption is -. The 6.8 L tank gives roughly 7 h at 50% load at rated load. Diesel consumption scales fairly linearly with load, so running at half load roughly halves hourly fuel use.
Can it run continuously?
Yes — diesel sets are built for sustained duty and are the normal choice where the machine runs several hours a day. Keep to the service intervals in the manual, particularly oil and filter changes: small diesel engines are far less forgiving of neglected oil than gasoline engines.
Can it be installed near houses or a clinic?
This is a silent-type set rated around 70–75 dB(A) at seven metres, the configuration normally specified for hospitals, hotels, offices and residential blocks. Installation still matters: a solid concrete pad and a position away from reflective walls will do as much as the canopy itself.